Multi-Server OPC Connectivity
Connect to up to 10 OPC Servers and log up to 10,000 signal points per server, with a total capacity of 100,000 points.
Connect Your Equipment to Your Database.
Turn Every Signal into Usable Data.
OPCTechs OPC to DB retrieves equipment signals from existing OPC Servers through an OPC interface and writes their values to a database at configurable intervals—creating a consistent, queryable history of process and equipment data.
Build on your existing OPC Server infrastructure. OPC to DB periodically collects selected signals and maps their values to defined fields in your chosen database.
From OPC connectivity and database mapping to configurable logging intervals and fallback values, the software provides the essential tools for structured signal storage.
Connect to up to 10 OPC Servers and log up to 10,000 signal points per server, with a total capacity of 100,000 points.
Map OPC tags to selected databases, tables, and fields. Supported database platforms include SQL Server, Microsoft Access, and PostgreSQL.
Interval Mode supports logging intervals from 1 to 86,400 seconds, with a configurable start delay of 5 to 1,800 seconds.
Use TrendTag.csv to define OPC tags, destination fields, and storage parameters. The OPCTechsTrendComp utility helps generate the corresponding database tables.
Define a FailValue to be stored when communication fails, and apply Scale and Offset parameters to transform signal values before writing them to the database.
View runtime status messages in LogView and configure data retention periods and scheduled record deletion through the configuration file.
Verify connectivity to existing OPC Servers and identify the PLC signal points to be logged.
Set database connection parameters and logging intervals, then map OPC tags to fields in TrendTag.csv.
Use OPCTechsTrendComp to validate the CSV configuration and create the required database tables.
Run OPCTechsTrend to record signal values at the configured interval, then check results in LogView and the destination database.
INI and CSV configuration files let you define database connections, destination fields, logging intervals, and fallback values to match your operational requirements.
Assign individual OPC tags to specific database table fields.
Apply a linear transformation to each value before storage.
Set the fallback value for communication failures and the automatic logging interval.
| OPC Tag | DB Field | FailValue | Scale | Offset |
|---|---|---|---|---|
| Device1.AI.F1_A_01 | F1_A_01 | -9999 | 1 | 0 |
| Device1.AI.F1_A_02 | F1_A_02 | -9999 | 1 | 0 |
| Device1.AI.F1_A_03 | F1_A_03 | -9999 | 1 | 0 |
Destination Database: DB_Test / Table: Trend
[INTERVAL] StartDelay = 10 ; Start delay (seconds) IntervalTime = 10 ; Logging interval (seconds) IntervalDelete = 180 ; Retention period (days) CompressHour = 0 ; Deletion time (hour) CompressMinute = 10 ; Deletion time (minute)
Value transformation before database storage:
Example: With an input value of 12.5, Scale = 2, and Offset = 5, the stored value is 30.
If communication fails, the configured FailValue can be recorded instead.
Maintain queryable historical records to support equipment reviews, process traceability, and operational analysis.
Periodically log PLC process parameters to a database for production condition reviews and historical traceability.
Consolidate signals from multiple OPC Servers to build a centralized history of equipment conditions and operating values.
Record electricity usage, temperature, and other measurements made available through OPC Servers at scheduled intervals.
Multi-server OPC connectivity, flexible field mapping, scheduled logging, and configurable data retention in one software solution.
| OPC Server Connections | Up to 10 servers |
| Data Point Capacity | Up to 100,000 points (10,000 per OPC Server) |
| Supported Databases | Microsoft SQL Server 2022 or later; Microsoft Access 2024 / Access for Microsoft 365; PostgreSQL |
| Supported Data Types | Bool (Bit), Int, Real, Float |
| Logging Interval | 1–86,400 seconds (Interval Mode) |
| Start Delay | 5–1,800 seconds |
| Value Scaling & Fallback | Scale, Offset, FailValue |
| Configuration Files & Utilities | OPCTechsTrend.ini, TrendTag.csv, OPCTechsTrendComp, LogView |
| Data Retention | Configurable retention period and scheduled record deletion |
| Supported Operating Systems | Windows 11 Pro / Windows Server 2022 or later |
OPC to DB connects through an OPC interface to read data from an existing OPC Server. It is designed for data acquisition and database logging; equipment signals must already be made available by an OPC Server.
Yes. The software supports up to 10 OPC Servers and 10,000 points per server, with an overall capacity of 100,000 data points. Deployment requirements depend on the connected equipment and site environment.
A configurable FailValue can be written to the corresponding database field when communication fails. This is a fallback-value function, not a store-and-forward mechanism for recovering data lost during an outage.
Yes. Interval Mode allows logging intervals from 1 to 86,400 seconds. The INI configuration file also provides settings for start delay and data retention.