OPC Data Aggregation, Bridging, Redundancy & Tunneling
Acting as a bridge between various OPC servers, DataWorX32 provides different OPC data channels. Once multiple I/O channels are established, DataWorX™32 will switch between a primary PC (node) and a backup PC on the network. Should the primary PC become disabled, DataWorX32 can automatically switch to the backup PC.
|
 |
 |
OPC Server to OPC Server Data Bridging |
 |
OPC-Based Redundancy |
 |
OPC Data Aggregation |
 |
Secure, and Patented, OPC Tunneling |
 |
|
|
|
 |
DataWorX32 and Applications: |
 |
| DataWorX-Data Aggregation |
|
DataWorX has the ability to act as a "OPC server" and a "OPC client" application. It allows to integrate different brands of OPC Server applications. Some OPC Server have limitation for the client amounts and some OPC Server only provide the lower version of OPC specification........ |
 |
|
| DataWorX-Redundancy |
|
DataWorX provides 100% OPC server redundancy using OPCTechs OPC servers to any OPC client through the network without requiring any programming. Alternative machines can be designated as secondary servers, should a primary server go offline........ |
 |
|
| |
|
| DataWorX-Data Bridging |
|
DataWorX can pass information from one device on to another; for example, data from one brand of PLC shared with another I/O device. In the past, one would have to write programs to translate and move data from one server to another. DataWorX32 provides this server-to-server data exchange, serving as an "OPC bridge" between two or more servers....... |
 |
|
| Application -OPC Data Bridging |
|
DataWorX32 can pass information from one device on to another; for example, data from one brand of PLC shared with another I/O device. In the past, one would have to write programs to translate and move data from one server to another....... |
 |
|
|
| Application -Redundancy |
|
DataWorX32 provides 100% OPC server redundancy using OPC servers to any OPC client through the network without requiring any programming. Alternative machines can be designated as secondary servers, should a primary server go offline... |
 |
|
| OPC UA: An End-User’s Perspective |
|
OPC UA (Unified Architecture) represents the OPC Foundation’s most recent set of specifications for Process Control and Automation system interconnectivity. This paper explains OPC UA from the perspective of the organization that will benefit from the connectivity, in other words.... |
 |
|
|
|
| |
|
| |
The Newest OPC Server... |
 |
  |
| |
 |
FESTO PLC |
 |
Supported PLC: |
Serial: FC30,FC34,FC400,FC440,FC600,FC640,FC660 |
| Ethernet: FC34,FC400,FC440,FC600,FC640,FC660 |
| Certification Testing: |
OPC (DA & AE )Compliance Tested-Festo Serial |
| |
OPC (DA & AE )Compliance Tested-Festo Ethernet |
|
|
|
|
|
| |
OPCTechs OPC Server Specifications... |
 |
 |
|
 |
Data Access V1.0, V2.05, V3.0 |
 |
Alarms and Events V1.1 |
 |
Data Access Automation Interface Standard V2.0 |
 |
OPC Common Definitions and Interfaces V1.0 |
 |
OPC XML-DA V1.0 |
 |
OPC Complex Data V1.0 |
 |
Provide Data Access and Alarms & Events two kind of OPC Server in one software |
 |
Provide various engineering Data Conversion |
 |
It provides multiple signals simulation function |
 |
Multi-threaded design with high performance |
 |
The users could use internet to connect with OPC Server through OPC XML-DA function |
 |
View Monitor:It’s easy to view the values of the devices after define the tags in the OPC server |
 |
Export / Import the configuration by Excel CSV file |
 |
It provides BOOL, INT, DINT, UINT, UDINT, REAL and STRING data types |
 |
It could define High / Low Alarm Limit and Digital Alarm Condition |
|
|
|